MBAS 0600/MICRO 17

Application-

  • Suitable for Process
  • Plants, Diesel Generators
  • Control Rooms
  • C & R Panel
  • Material handling Systems
  • Instrumentation Panel
  • Battery Charger panel
  • Compressor control panel

Overview-

The Functional Features

  • Fixed Sequence ( S1/S2/S3/S4)
  • Potential free dry contact inputs
  • NO/NC inputs selectable configuration
  • Relay output for external Audible Hooter 3rd Relay optional for either of below mentioned features
    a) Ring back hooter
    b) Supervisory control
  • Minilec Standard Communication Protocol

The Design Features

  • Single chip microcontroller logic
  • Opto isolated inputs and outputs
  • Super Bright LED window illumination
  • High Noise immunity / isolation
  • Switch mode power supply
  • Self surveillance watchdog LED

The Constructional Flexibility

  • Conforming to DIN panel cutouts
  • Replaceable snap-on window capsules
  • Two different window size
  • Molded enclosures

Optional Features

  • Any custom built operating sequences
  • Manned / Unmanned function
  • MODBUS RTU/ASCII Protocol
  • Fault Follower contact output per fault Input (NO or NC)
  • Supply fail indication / annunciation Built in
  • Built-in control push buttons
Category:

Description

Technical Specifications

Supply Voltage 24 / 30 / 48 / V DC, 20-60 V AC/DC, 90-270 V AC / DC

Windows 4 / 6 / 8 / 12 / 16 / 18 / 22 / 24 / 32

Window Sizes 30 x 30mm / 30 x 65 mm

Display Device Super bright high efficiency low power consuming LED’s

Facia Type Individual windows Front Replaceable

Window/LED Colours RED, Yellow, Green, White & Blue

Flash Rate Fast – 60 flashes/min. Slow – 30 flashes/min.

Response Time 40 msec.

Input Signal Potential free contacts (NO or NC site selectable)

Grouping Trip / Non Trip site selectable

Interrogation Voltage+ 12 V DC

Output Contacts 1 NO + 1 NO + 1 NO (optional)

Architecture Integrated

Operational Sequences
(site selectable) Auto/Manual/First-up/Ringback (optional) OR any other sequence on request

Operational Temp 0-60 degrees C

Optional AC-DC fail Annunciation or Indication / Repeat Relays / RS232 – 485 Port

Power Consumption 1.5 Watts per Window (Max)

Dimensions (mm)

  • Panel Cutout (L x W)
    Overall (L x W x D)

    1D
    138 x 68
    144 x 72 x 215
    2D
    138 x 138
    144 x 144 x 215
    3D
    138 x 210
    144 x 216 x 215
    4D
    138 x 282
    144 x 288 x 215

Wherever not specified Contact Rating : 5A @ 230 V AC (resistive) * CE marked products available on request.